ECS Forwarding Agent(3.0)
In order to send UDRs to ECS, a workflow must contain an ECS forwarding agent and the invalid UDRs have to be routed to it. It is recommended to use a preceding Analysis or Aggregation agent to associate an Error Code with the UDR.
The ECS forwarding agent is applicable for UDRs only. Batches are handled in the following ways:
- Through theÂ
cancelBatch
APL function. - By setting your workflow to never abort in the workflow properties.
- After a certain amount of consecutive workflow aborts.
- Using the Route Raw Data option in the Decoder agent.
Note!
From the ECS forwarding agent, it is possible to pass on MIM values to be associated with the UDRs in the ECS Inspector.
Configuration
The ECS Forwarding agent provides you with an option to log Meta Information Model (MIM) for the UDRs that are to be sent to the ECS as well as allow you to configure the thread buffer. The configurations you can set for the agent are as follows:
ECS Tab
Setting | Description |
---|---|
Logged MIMs | MIM values to be associated with a UDR when sent to ECS. |
Thread Buffer Tab
See the description in the section, Thread Buffer Tab, in Workflow Template.
Input/Output
The agent does not emit or retrieve any commands.
Input/Output data
The input/output data is the type of data an agent expects and delivers.
The agent consumes selected UDR types.
MIM
For information about the MIM and a list of the general MIM parameters, see Administration and Management(3.0).
Publishes
MIM Value | Description |
---|---|
Agent Name | The name of the agent. |
Inbound UDRs | The number of UDRs routed to the agent. |
Accesses
The agent does not itself access any MIM resources.
Agent Message Events
There are no agent message events for this agent.
Debug Events