Validate the Helm Chart Contents
To ensure there are no errors in the Helm chart content, you can run the following:
Code Block $ helm lint usage-engine-private-edition
You can also run the helm template chart to see the yaml file with modified values:Code Block $ helm template usage-engine-private-edition
Upgrade all pods.
- Use the new License Key for the upgrade. In case you have not received a new License Key, see the Release Note for the alternative method.
- In the case the upgrade fails, it will rollback automatically. The new resources from the upgrade will be removed automatically.
Code Block Before you upgrade, validate the helm chart with a dry-run: Note that <release_platform> is the unique names that was defined at the installation. $ helm upgrade <release_platform> usage-engine-private-edition --set-file licenseKey=<licensekey_file> --dry-run --debug --namespace <namespace> If the validation is ok, continue with the upgrade: $ helm upgrade <release_platform> usage-engine-private-edition --set-file licenseKey=<licensekey_file> --atomic --cleanup-on-fail --debug --namespace <namespace>
Verify the installation. STATUS Running. The READY state (ready/desired) should be 1/1, 2/2 and so on. It can can take a few minutes before everything is in up and running.
Code Block # Verify pods $ kubectl get pods --namespace <namespace> #Example NAME READY STATUS RESTARTS AGE uepe-operator-controller-manager-646b766d44-2s9sl 2/2 Running 0 154m uepe-operator-controller-manager-646b766d44-mmzhs 2/2 Running 0 154m desktop-online-7ff989968b-9hd2b 1/1 Running 0 154m platform-0 1/1 Running 0 154m # Verify service contexts to connect $ kubectl get services --namespace <namespace> #Example NAME TYPE CLUSTER-IP EXTERNAL-IP PORT(S) AGE uepe-operator-controller-manager-metrics-service ClusterIP 10.107.192.50 <none> 8443/TCP 154m uepe-operator-controller-manager-service ClusterIP 10.100.197.208 <none> 443/TCP 154m desktop-online NodePort 10.101.65.181 <none> 80:31200/TCP,443:31300/TCP 154m platform NodePort 10.96.40.10 <none> 9000:31600/TCP,6790:31700/TCP 154m
Note |
---|
...
Note! The output will show the exposed ports when you run when you connect to the Desktop |
...
. |
Note |
---|
...
Manual Downgrade In the case you need to do a manual downgrade of the system, see Downgrade( |
...
4.0). |
Manual ECD rolling update
If Automatic Rolling Update was never defined for the ECDs, you need to manually upgrade the ECDs to the new image in Desktop Online by clicking Upgrade in the EC deployment interface.
...