Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 4 Next »

You open the Pulse agent configuration dialog from a workflow configuration: you can right-click the agent icon and select Configuration..., or double-click the agent icon.

Interval Tab

The Interval tab contains configuration settings related to the interval type and the related time parameters that control how often the pulse UDRs will be generated.

The Pulse agent configuration dialog - Interval tab

SettingDescription

Time Unit

Select the time unit that is applicable to the time fields on this tab.

Interval Type

Select an interval type that corresponds with the desired generation of Pulse UDRs.

Fixed - UDRs are generated at a fixed time interval

Linear - UDRs are generated at a linearly increasing or decreasing time interval.

Gaussian - UDRs are generated according to a Gaussian probability distribution.

Poisson - UDRs are generated according to a Poisson process.

Single - A single UDR is generated at workflow start.

Interval

Enter the interval between the pulses according to the specified time unit.

Interval is available when the selected Interval Type is Fixed.

Start

Enter the start interval between pulses.

Start is available when the selected Interval Type is Linear.

Stop

Enter the final interval between pulses.

Stop is available when the selected Interval Type is Linear.

Rate

Enter the value that is incremented or decremented from the interval when a Pulse UDR is generated. Use a positive value to increment and a negative value to decrement.

Rate is available when the selected Interval Type is Linear.

Central Interval

When the selected Interval Type is Gaussian, enter the median interval between Pulse UDRs in the probability distribution.

When the selected Interval Type is Poisson, enter 1/(expected number of Pulse UDRs per time unit).

Example - Poisson interval type

 Expected number of Pulse UDRs is five (5) per second.

1/5=0.2 seconds between UDRs

Select MILLISECONDS in Time Unit and enter 200 in Central Interval.

Central Interval is available when the selected Interval Type is Gaussian or Poisson.

Width

Enter the standard deviation of the probability distribution. When you use a low value, the intervals tend to be close to the value of the Central Interval. Use a high value to spread the intervals over a wider range.

Width is available when the selected Interval Type is Gaussian.

Note!

The real value of the configured interval length is approximated and should not be used for timing-sensitive tasks. To get the most accurate pulse-delay, use fixed time intervals.

Data Tab

The Data tab includes settings that control the contents of the Pulse UDRs.

The Pulse agent configuration dialog - Data tab

SettingDescription
Random With Range

Select this radio button to populate the Sequence field in the Pulse UDRs with a random integer. The range of the values are specified in the Range fields.

Sequential

Select this radio button to populate the Sequence field in the Pulse UDRs with a value from an infinite sequence starting at 0. The sequence is reset when a workflow is restarted.

Sequential With Range

Select this radio button to populate the Sequence field in the Pulse UDRs with a value from a finite sequence. The range of the values are specified in the Range fields. The sequence is reset when a workflow is restarted or when the end value is reached.

RangeEnter the start and end value of the sequence. You can use negative values but the end value must be greater than the start value.
Random DataSelect this radio button to generate random data in the Data field of the Pulse UDRs. The data is generated when the workflow starts and each UDR will contain the same data.
SizeEnter the size of the random data and select the byte unit from the drop-down list.
Enter Data

Enter the data that is to be populated in the Data field of the Pulse UDRs.

  • No labels