  1. Start all EC/ECSAs that were shut down during the upgrade.

    $ mzsh startup <ec names> <ecsa names>
  2. Restart the disconnected ECSAs and start the real-time workflows.

    In order to minimize downtime, restart the disconnected ECSAs one by one.

    To stop running real-time workflows and restart an ECSAs:

    $ mzsh shutdown <ecsa name>
    $ mzsh startup -f <ecsa name>


    The file $MZ_HOME/lib/picostart.jar will be updated on the ECSAs.
     

  3. Start the workflows on the restarted EC/ECSAs.
     
  4. Enable all workflow groups, from the Execution Manager in Desktop, or by entering the mzsh wfgroupenable command, for example:

    $ mzsh mzadmin/<password> wfgroupenable \*