Licensing Information
The feature described in this documentation is optional and might not be part of the edition covered by your company's license.
When the data is sent from the Meter processor, which is known as flushing the record, a record in json format will be sent for each meter associated with the Meter processor.
Regardless of whether the meter was updated or not during the last metering period, the meter will always be flushed when its period ends. Meters will not be flushed after the Active to: date and time has passed for the associated meter type except for meters that have been updated during the current metering period.
Usage audit is generated when the input data is output from Meter processor.
The metered record can be viewed in JSON format in the Meter Inspector
The following fields are included in the record sent to downstream systems in JSON format:
Field | Purpose |
---|---|
id | The unique ID of the meter. |
userId | The unique ID of the user the meter belongs to, for example an email address, user name, or MSISDN number. |
meterTypeId | The unique ID of the meter type that the meter aggregates usage for. |
meterTypeName | The name of the meter type this meter is using. |
timezone | The timezone that should be applied for reset time. Defined in the meter type for this meter. |
meterKey | The meter key for the Meter processor aggregating the usage for the meter. |
value | The current value of the meter, updated based on the guiding rules and aggregation type defined in the meter type. |
unit | The unit in which this meter measures usage. Defined in the meter type for this meter. |
createdAt | The UTC timestamp for when the meter was created. |
updatedAt | The UTC timestamp for when the meter was last updated. |
periodStart | Tha UTC timestamp for when the metering period has started. This is calculated based on when last period has ended. |
periodEnd | The UTC timestamp for when the metering period has ended. This is calculated based on reset schedule. |
groups | A granular breakdown of the aggregated values, grouped by the guiding rules defined in the Meter Configuration. Each group is represented by an array containing the parameters |
carryFirst | The first occurrence of one or many fields that should be carried over from the usage record. This is configured in Other operations in the Meter Configuration. |
carryLast | The last occurrence of one or many fields that should be carried over from usage record. This is configured in Other operations in the Meter Configuration. |
deleteOnReset | If this is set to true, the meter will be deleted when ongoing metering period ends. This can be updated using the update meter API. |
meterMetaData | This is additional meta information related to the usage ingestion example, datetime when the first and last record matched this meter. |
Example - Metered Output Record
{ "carryFirst": { "country": "Norway" }, "carryLast": { "timestamp": "2023-07-05T22:01:04.431Z" }, "createdAt": "2023-07-01T00:00:00.000Z", "deleteOnReset": false, "groups": [ { "fields": { "API name": "createUser" }, "key": "API name:createUser", "value": 10 }, { "fields": { "API name": "updateCounter" }, "key": "API name:updateCounter", "value": 15 } ], "id": "8a76066d-ff29-417c-a18e-abde22e44310", "meterKey": "a1f8797b-c827-4483-b6cf-6d3d3baa18a7", "meterMetaData": { "firstEvent": "2023-07-01T13:37:11.111Z", "lastEvent": "2023-07-05T22:01:04.431Z" }, "meterTypeId": "645ed240-02b5-400c-9a3c-21857e8f2ac4", "meterTypeName": "Usage based API counter", "periodEnd": "2023-08-01T00:00:00.000Z", "periodStart": "2023-07-01T00:00:00.000Z", "timezone": "Etc/UTC", "unit": "requests", "updatedAt": "2023-07-05T22:01:04.431Z", "userId": "user0@example.com", "value": 25 }
Meter Reset
When flush happens, the values of the meters are also reset to their initial value, for example a value is set to 0 or groups are removed etc, to empty the bucket. At the same time, meters are prepared for the next metering period and Period start and Period end is updated based on when flush happen and the Reset schedule.
If the meters are flushed by Period end in the Meter Processor , then the new period start is set to when the last period ended, and the period end is calculated based on the Reset schedule of the respective meter type.
Example - Meter Type has Reset Schedule Everyday at Midnight
Ongoing period: Period start - 1st Jan 00:00 and Period end 2nd Jan 00:00.
If stream runs on 2nd Jan on 02:00, New period: Period start at 2nd Jan 00:00 and Period end at 3rd Jan 00:00.
If stream does not run 2nd Jan and runs on 3rd Jan at 02:00, New period: Period start at 2nd Jan 00:00 and Period end at 4th Jan 00:00.
This is because before the incoming usage data is processed, the stream scans for meters whose periods have ended and flushes them, so in latter case where the stream runs on 3rd Jan, the usage data from the 2nd of Jan post midnight is included in the new period and usage data up until the 2nd at midnight is already aggregated in the metered and flushed record.
If the meters are flushed by Stream execution in the Meter Processor , the period end of the flushed metered record is set to the time of the flush. The new Period start of the meter in the stream is also set to the time of the flush, and the Period end is calculated using the meter type Reset schedule.
Period start and Period end for a meter can be checked in the Meter Inspector.