Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

The contents of the menus in the menu bar may change depending on which configuration type that is opened. The Inter Workflow profile uses the standard menu items and buttons that are visible for all configurations, and these are described in Configuration [hide]mz9[/hide]Build View.

The External References button in the menu bar is specific for Inter Workflow profile configurations.

ItemButtonDescription

Select this menu item to Enable External References in an agent profile field. For further information, see the section Enabling External References in an Agent Profile Field in 8.10 External Reference Profile .

The Inter Workflow profile configuration contains the following settings:

ItemSettingDescription

Storage Host

From the drop-down list, select either Automatic or an activated EC group.

Using Automatic means that the storage will use the EC Group where the first workflow accessing this profile is started. Following workflows using the same profile will use the same EC Group for storage until the first workflow accessing the profile is stopped. The EC Group where the next workflow accessing this profile is started will then be used for storage. The location of the storage will therefore vary depending on the start order of the workflows.

Info
titleExample

Below is an example of a scenario where Automatic is used as storage host with the following setup:

  • Workflow 1 is running on EC Group 1 with Interworkflow Forwarding agent

  • Workflow 2 is running on EC Group 2 with Interworkflow Collection agent
     

  1. Workflow 2 is started.

    EC Group 2 is used for storage
     

  2. Workflow 1 is started.

    EC Group 2 is still used for storage.
     

  3. Workflow 1 is stopped.

    EC Group 2 is still used for storage.
     

  4. Workflow 2 is stopped.

    No EC Group is used for storage.
     

  5. Workflow 1 is started.

    EC Group 1 is used for storage.


Note
titleNote!

The workflow must be running on the same EC as its storage resides. If the storage is configured to be  Automatic , its corresponding directory must be a shared file system between all the EC Groups.


Root Directory

Absolute pathname of the directory on the storage handler where the temporary files will be placed.

If this field is greyed out with a stated directory, it means that the directory path has been hard coded using the mz.present.interwf.storage.path property. This property is set to false by default.

Info
titleExample - Using the mz.preset.interwf.storage.path property

To enable the property and state the directory to be used:

Code Block
mzsh topo set val:common.mz.preset.interwf.storage.path '/mydirectory/iwf'


To disable the property:

Code Block
mzsh topo unset val:common.mz.preset.interwf.storage.path


For further information about all available system properties, see 2.6 System Properties .

Max Bytes

An optional parameter stating the limit of the space consumed by the files stored in the Root Directory. If the limit is reached, any Inter Workflow forwarding agent using this profile will abort.

Max Batches

An optional parameter stating the maximum number of batches stored in the Root Directory. If the limit is reached, any Inter Workflow forwarding agent using this profile will abort.

Compress intermediate data

Select this check box if you want to compress the data sent between the Inter Workflow agents.

The data will be compressed into *.gzip format with compression level 5.

Named MIMs

A list of user defined MIM names. These variables do not have any values assigned. They are populated with existing MIM values from the Inter Workflow forwarding agent. This way, MIMs from the forwarding workflow can be passed on to the collecting workflow.

...