Setting | Description | |||||
---|---|---|---|---|---|---|
Prefix | Enter the data files name prefix | |||||
Number Positions | Select the length of the number-part in the data file name as follows:
For example: If you select 0001, data file number 99 will include the following four digits: 0099 . | |||||
Ends With VDS Device No. | Select this check box to create data file names that end with VDS device No. | |||||
Server Port | Enter the port number for the server to connect to, on the remote Switch .
| |||||
Number Of Retries | Enter the number of attempts to reconnect after temporary communication errors. | |||||
Retry Interval (ms) | Enter the time interval, in milliseconds, between connection attempts. | |||||
Force Delay (s) | Select this option to force a delay (in seconds) between the TTTCOF write and the TTSCOF read. The maximum value is 3600. The default value is 0. | |||||
Decompress Files | Data files are decompressed by default. If you want the data files to be compressed, deselect this check box. | |||||
Local Data Port | Enter the local port number that the agent will listen to for incoming data connections. This port will be used when communication is established in Active Mode. If the default value, zero, is not changed, the FTP server will negotiate about the port the data communication will be established on. | |||||
Active Mode (PORT) | Select this check box to set the FTP connection mode to ACTIVE. Otherwise, the mode is PASSIVE. | |||||
Transfer Type | Select either Binary or ASCII transfer of the data files.
| |||||
FTP Command Trace | Select this check box to generate a printout of the FTP commands and responses. This printout is logged in the Event Area of the Workflow Monitor. Use this option only to trace communication problems, as workflow performance might deteriorate. | |||||
Accept New Host Keys | Select this check box if you want the existing host key to be overwritten when the host is represented with a new key. The default behavior is to abort when the key mismatches.
|
TTSCOF Settings Tab
FTP/DX200 collection agent configuration - TTSCOF Settings tab
The TTSCOF Settings tab includes configuration settings that allows you to adjust the default settings for the FTP DX200 agent
Setting | Description | |||||
---|---|---|---|---|---|---|
Collect when file is present on only one WDU | With this setting you can select to allow files to be collected, even though they are only present on one WDU. This may be useful if one of the WDUs cannot be reached for some reason. Default is No, which means that files will only be collected if they are present on both WDUs.
| |||||
WDU0 Path | In this field you can specify the path to WDU0. This setting is optional. | |||||
WDU1 Path | In this field you can specify the path to WDU1. This setting is optional. | |||||
Select default collection WDU | Select the WDU you want to use as default in this list. WDU 1 is default. | |||||
Collect files with bit 5 | In this list you can select if you only want to collect files where bit 5 IS NOT set (Must not be set), or where bit 5 IS set (Must be set), or if you always want to collect files regardless of whether bit 5 is set or not (May be set). | |||||
Collect files with bit 6 | In this list you can select if you only want to collect files where bit 6 IS NOT set (Must not be set), or where bit 6 IS set (Must be set), or if you always want to collect files regardless of whether bit 6 is set or not (May be set). | |||||
Collect files with bit 7 | In this list you can select if you only want to collect files where bit 7 IS NOT set (Must not be set), or where bit 7 IS set (Must be set), or if you always want to collect files regardless of whether bit 7 is set or not (May be set). |
Scroll ignore | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ||||||||||||||||