The Sybase JDBC driver that is included in the SDK has to be downloaded to the Platform in order to connect to a Sybase IQ database from .
...
- Go to the SAP Software Solutions web page for information about the SDK and included drivers:
https://www.sap.com/index.html.
- Place the downloaded jar file in the
$MZ_HOME/3pp directory
.
- Restart the Platform and EC/ECSAs.
Close Pooled Connections
The APL function closePooledConnections
enables you to close a pooled connection with the Sybase IQ server. This feature helps you eliminate invalid connections.
...
Info | |||||||
---|---|---|---|---|---|---|---|
| |||||||
|
By default there is no timeout value defined for the socket tied to a database connection. This means that a running query could get stuck, in case the database suddenly becomes unreachable. To specify a timeout valueThere are two properties available for handling the timeout of socket connections and socket threads:
sybase.jdbc.socketread.timeout
with default value 180000 (3 minutes in milliseconds)sybase.jdbc.socketconnect.timeout
with default value 30000 (30 seconds in milliseconds)
To specify other timeout values, in milliseconds, set the Execution Context property sybase.jdbc.socketread.timeout
in properties in the relevant <pico>.conf
file.
Info | |||||||
---|---|---|---|---|---|---|---|
| |||||||
|
Note | ||
---|---|---|
| ||
When using the timeout property you must ensure that you set a limit that exceeds your longest-running query, otherwise, you might terminate a connection while it is executing a query. |
...