Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Apart from simply sending a UDR or batch to ECS, a workflow can be configured to associate user-defined information with the ECS data. For the UDRs this is Error Code and MIM information. For cancelled canceled batches, the Error UDR and Cancel Message may contain user-defined information.

Note
titleNote!

Only a reference, not the data itself, is saved in the database. Physically, ECS data is saved in the directory defined by the property  mz.ecs.path  found in platform.conf. The default path is MZ_HOME/ecs.

If the  mz.ecs.path  parameter is changed, the changes will take effect the next time data is inserted into ECS. Existing ECS data is left at its current location and must not be moved. If required to do so anyway, move the content of the old  mz.ecs.path  directory to the new , one and create a soft link in the old directory pointing out the new location.

...

Note
titleNote!

Take special precaution precautions when updating the Ultra formats. It is not possible to collect data from ECS if the corresponding UDR has been renamed. If the format definition has changed, you can still collect the data.

Changes to the formats are handled as follows:

  • Added or renamed fields will be assigned default values.
  • Removed fields will be ignored.
  • Fields that have changed data types will be assigned default values.


Scroll ignore
scroll-viewportfalse
scroll-pdftrue
scroll-officefalse
scroll-chmtrue
scroll-docbooktrue
scroll-eclipsehelptrue
scroll-epubtrue
scroll-htmlfalse

The section contains the following subsections: