Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Insert excerpt
License
License
nameLicensing Information The feature described in this documentation is optional and might not be part of the edition covered by your company's license.
nopaneltrue

When you double-click the Meter meter processor function, the function’s configuration Meter dialog opens.

...

In the Meter key field above the settings in the Configuration tab, an automatically created Meter key will be displayedThis dialog consists of three different parts;

  • The Configuration tab, where you configure the processor

  • The Inspect tab where you can see details about the meters associated with the meter processor along with their current values, see Meter Inspector

  • A Preview section which shows what the input and output data looks like and can be used for testing the solution.

...

When meter processor is added to a stream a unique Meter key is created and is displayed in the Configuration tab in a Meter key field. This key is unique for each Meter per meter processor, and is one of the parameters used when creating meters using the APIs, see API Reference, and next Managing Meters with the API . Next to the field is a copy.png Copy button that you can use to copy the key when creating meters.

Note!

If you import a stream with a Meter meter processor which that is a duplicate of an existing stream, a new Meter key willl will be generated to ensure they are unique. The meters attached to meter processors are not imported when importing a stream.

The Configuration tab contains the following settings:

Guiding

...

Rules

The Meter Processor meter processor must have at least one guiding rule configured. You can add additional guiding rules by clicking the add-guiding-ruleImage Modified button at the bottom of the configuration screen. The maximum number of guiding rules is 10. . You can configure up to 10 guiding rules. Since guiding rules are executed based on a defined order, it is possible to re-order them by dragging them up and down.

Each guiding rule contains the following settings.

Setting

Description

Guiding rule

Name

Enter an intuitive name for the guiding rule in this field.

Condition setting

Select if you want to define customized conditions for the rule or not by selecting either No conditoncondition or Custom condition.

If you select No condition, nothing more is required, but if you select Custom condition, a new section called Condition n will appear that you can expand and enter any conditions you want to be met for the usage to be countedmetered:

condition2.png

Each condition is configured with three settings:

  • Field - In this the drop-down - list you , select a field in the usage data that you want to base the counting metering on. You can either select an existing field or create a new field by entering a new field in the Add Field field and clicking If the desired field is not visible in the drop-down, you can use Add Field in the drop-down then click on the + button to add your own.

  • Type of field - Select the field type in this drop-down-list; string, number, or boolean

  • Value - Enter the field value that you want to be matched for usage countingare expecting for the usage calculation.

For example:

Field: location download status
Type: string
Value: Bahamas complete

The field matching is case-sensitive. The name of the condition will now be converted to show your configuration which will make it easier to see the configured condition even after collapsing it.

You can configure additional conditions by clicking on the add-condition.png button at the bottom of this section. If you have more than one condition, you can select to have either AND as a separator or OR, but not a combination of the two.

If the usage data record does not match the condition and is filtered out then it will be evaluated against the next guiding rule, if configured.

Category to match

Select which category you want to count aggregate usage for in this drop-down.

The Meter Processor meter processor is referring to categories instead of individual Meter Types meter types which provides you with the possibility to add, remove, or update Meter Types whithout meter types without having to update the configuration of the Meter Processormeter processor.

All existing categories configured in Meter Types meter types will be displayed, see Creating Meter Types.

If the usage data record does not find the meter available in this category then it will be evaluated against the next guiding rule, if configured.

Group by

Group by n

If you want to group the To get the breakdown of the metered usage based on a specific field, for example region, the download type in a streaming service (movie, show, or season), click on the Group by n drop-down.

group-by.png

In this drop-down-list Here you can select the field(s) you want to group the usage by. You can either select an existing field or create a new field by entering a new field in the Add Field field and clicking If the desired field is not visible in the drop-down, you can use Add Field in the drop-down then click on the + button to add your own. The maximum number of fields you can add for each Group by n section is 5.

You can enter several add up to 5 Group by n sections by clicking on the + Add group by button. The maximum number of Group by n sections is 5.

For more details of the “Group by” configuration, see Flushing Metered Records

Other operations

If you want to perform other operations, to send additional information along with your metered record to downstream systems you can click on the Add operation button to . This will display a section for defining the operations that you want to be made:carried out.

operations.png

you can add up to 10 operations in a guiding rule. For details of the output of “other operations” configuration, see Flushing Metered Records

Operation

Select which type of operation you want to perform:

  • Carry first - Will pick the value of the stated field from the first record where it occursinput record that matches the meter.

  • Carry last - Will pick the value of the stated field from the last record where it occursthat matches the meter.

Field

Select the field you want to perform the Carry first or Carry last operation on.

If the desired field is not visible in the drop-down, you can use the Add Field in the drop-down then click on the + button to add your own.

To view all guiding rules together in a table format, click the View all button on the top right of ‘guiding rules

Flush By

The Flush by setting determines when flush happens, that is when the aggregated output data records are sent to downstream systems. You have two options;

  • Period end - This option is used when you want to aggregate over time, usually in sync with a billing cycle. If you select this option, the meters will be flushed and reset when the current period of the meter has ended. The period end of the meter is determined by the Reset schedule defined for the respective meter type.

  • Stream execution - This option is commonly used when testing the usage metering solution with integration when you want to output the metered record from the meter processor immediately. If you select this option, all meters will be flushed and reset at the end of stream execution. See Execution of Usage Metering Streams for further information about stream execution considerations. This option is not available for real-time streams.

This setting impacts when the flush is performed and the calculation of the next metering period. For more information see, Meter Reset in Flushing Metered Records and Real-time and batch execution inExecution of Usage Metering Streams.

Preview

Click on the preview.pngImage Added to see a preview of the Input and Output data in the left part of the meter dialog.

You can

...

select to view the data in the following formats:

  • Input data: Table, tree

  • Output data: Table, tree

The preview is generated using a fresh state of meters. It does not matter what the value of the meter in the system is, it always takes the meter’s initial state.

Preview functionality works best with a limited set of meters and meter types. A maximum of 200 entries will be shown in the preview. If more entries exist the preview will show a random selection of entries. Only the 10 most recently updated meters will be displayed in the output.

The log tab on output data helps with the debugging of issues that may occur due to incorrect fields or guiding rules. The log tab shows the number of records that will be sent to data correction because they have not matched any meter or because they are missing mandatory input fields.