Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Version published after converting to the new editor

The Pulse agent configuration contains the following tabs:

...


FieldDescription

Time Unit

Select the time unit that is applicable to the time fields on this tab.

Interval Type

Select an interval type that corresponds with the desired generation of Pulse UDRs.

Fixed - UDRs are generated at a fixed time interval

Linear - UDRs are generated at a linearly increasing or decreasing time interval.

Gaussian - UDRs are generated according to a Gaussian probability distribution.

Poisson - UDRs are generated according to a Poisson process.

Single - A single UDR is generated at workflow start.

Interval

Specify the interval between the pulses according to the Time Unit selected above. 

Interval is available when the selected Interval Type is Fixed.

Start

Specify the start interval between pulses.

Start is available when the selected Interval Type is Linear.

Stop

Specify the final interval between pulses.

Stop is available when the selected Interval Type is Linear.

Rate

Specify the value that is incremented or decremented from the interval when a Pulse UDR is generated. Use a positive value to increment and a negative value to decrement.

Rate is available when the selected Interval Type is Linear.

Central Interval

When the selected Interval Type is Gaussian, enter the median interval between Pulse UDRs in the probability distribution.

When the selected Interval Type is Poisson, enter 1/(expected number of Pulse UDRs per time unit).

Example - Poisson interval type

Expected number of Pulse UDRs is five (5) per second, so 0.2 seconds between UDRs.

Select MILLISECONDS in Time Unit and enter 200 in Central Interval.

Central Interval is available when the selected Interval Type is Gaussian or Poisson.

Width

Enter the standard deviation of the probability distribution. When you use a low value, the intervals tend to be close to the value of the Central Interval. Use a high value to spread the intervals over a wider range.

Width is available when the selected Interval Type is Gaussian.



Note
titleNote!

The real value of the configured interval length is an approximate and must not be used for time-sensitive tasks. To get the most accurate pulse-delay, use fixed time intervals.

Data tab


The Data tab includes settings that control the contents of the Pulse UDRs. The Data tab has the following fields:

...