You open the Azure Event Hub Consumer agent configuration dialog from a workflow configuration: you can right-click the agent icon and select Configuration..., or double-click the agent icon.


Azure Event Hub Consumer agent configuration
 

SettingDescription
ProfileSelect the Azure profile that has been configured with the connection details for the Azure Event Hub. For more information about how to configure the profile, refer to 1. Azure Profile.
Partition

Enter the partition name of the event hub to be used by the agent. This field is optional.

Storage DirectoryEnter the directory path of where the data are to be collected from the EC server that the Event Hub Consumer agent will be using.
Consumer GroupEnter the name of the consumer group the agent will be retrieving from.
Start at latest (from end)

Events are selected from the last offset from when the workflow was started. If you select this option, there is a risk that data can be lost after a restart.

This applies to the first instance of "out of sequence range" when the workflow is initiated.

Start at earliest (from beginning)

Events are collected from the first offset. If you select this option, there is a risk that events will be processed multiple times after a restart. This applies to the first instance of "out of sequence range" when the workflow is initiated.

Advanced Tab

The Advanced tab contains additional settings , which allow you to pre-define the events collection for subsequent instances of "out of sequence range" that may arise while the workflow is running.for checkpointing the offset of events collection when the workflow is initiated. When a directory path is specified in the Storage Directory field, these settings shall override the settings for "Start at latest (from end)" and "Start at earliest (from beginning)" in the General tab. 

Image Modified

Azure Event Hub Consumer agent - Advanced tab

SettingDescription
Ignore out of sequence rangeSelect this checkbox to enable the following options which allow you to preset the events collectionto predefine where you would like the reading of offset to take place after a workflow restarts
Start at latest (from end)

Events are selected from the last offset from when the workflow was started. If you select this option, there is a risk that data can be lost after a restart.

This applies to the subsequent instances of "out of sequence range" while the workflow is running.

Start at earliest (from beginning)

Events are collected from the first offset. If you select this option, there is a risk that events will be processed multiple times after a restart.This applies to the subsequent instances of "out of sequence range" while the workflow is running.