Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1.  Disable all Workflow Groups, from the Execution Manager in Desktop, see 6.7 Execution Manager, or by entering an mzsh command, for example:

    Code Block
    themeEclipse
    $ mzsh mzadmin/<password> wfgroupdisable \*


    Note
    titleNote!
    If you use the wfgroupdisable command, make sure that you enable all system tasks again when you are done. 


  2. Stop all workflows that are not disconnected and let them finish execution.

  3. Ensure that all users shut down all connected Desktops.

    If you want to see which Desktops that are connected, you can use the following command:

    Code Block
    themeEclipse
    $ mzsh mzadmin/<password> pico -view


    Note
    titleNote!
    This command will also display other pico instances, such as Execution Contexts.


  4. Shut down all EC and the ECSAs that have not been disconnectedECs.

    Code Block
    themeEclipse
     $ mzsh shutdown <ec name> <ecsa name>




If you are running services on SCs, and want to minimize downtime, leave the SCs running during the upgrade procedure.