Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

An encoder specifies how data is to be encoded. The syntax for the  encoders  is as follows:

Code Block
encoder <encoder_name> : <encoder options>; 

The encoder options are:


 

OptionDescription

out_map(<map name>)

Specifies what out-maps to use. At least one is required.

block_size(<size>)

Specifies that this is a blocked format with a certain block size

terminated_by(<terminator>)

Specifies the block filler used. This option has no effect if the block_size has not been specified.

When encoding a record, the encoder tries each out-map in the order specified. If the out-map can encode the record, then this out-map is used, otherwise the next out-map is tried.

An out-map can encode the data if:

  1. The record type matches the internal type specified in the out-map.

  2. All format specific requirements are met. At the moment this evaluation is performed only for sequential data with an identified_by condition. Only data where the mapped fields meet the identification rule will be accepted. This is to support mapping to different external record types from the same internal type.

    Note
    titleNote!

    There is no such thing as a constructed encoder. If the records are required to be forwarded in a specific order, an APL agent handling the output logic must precede the Encoder.

 


Scroll ignore
scroll-viewportfalse
scroll-pdftrue
scroll-officefalse
scroll-chmtrue
scroll-docbooktrue
scroll-eclipsehelptrue
scroll-epubtrue
scroll-htmlfalse


Next:



Scroll pagebreak