The Alarm Conditions that you can choose from are:
- Host Statistic Value
- Pico Instance Statistic Value
System Event
- Unreachable Execution Context
Workflow Alarm Value
Workflow Execution Time
Workflow Group Execution Time
Workflow Throughput
Host Statistic Value
The Host Statistic Value condition enables you to setup an Alarm Detection for the various statistic values by host.
The Host Statistic Value condition
Item | Description |
---|---|
Event Properties | |
Host | Select a host for applying the alarm condition. |
Statistic Value | The statistic criteria on host includes:
|
Limits | Specify the condition for the alarm to be triggered. The options are Exceeds or Falls Below the selected statistic value. |
Pico Instance Statistic Value
The Pico Instance Statistic Value condition enables you to setup an Alarm Detection for the various statistic values by pico instances.
The Pico Instance Statistic Value condition
Item | Description |
---|---|
Event Properties | |
Pico Instance | Select a Pico instance for configure alarm, it can be Platform, EC |
Statistic Value | The statistic criteria on Pico instance includes:
|
Limits | Specify the condition for the alarm to be triggered. The options are Exceeds or Falls Below the selected statistic value. |
System Event
The System Event condition enables you to setup an Alarm Detection for the various Event types.
...
Info | |||||
---|---|---|---|---|---|
| |||||
The alarm will be triggered by every 4th occurrence of a "Workflow State Event" during the last 24 hours. |
Unreachable Execution Context
The Unreachable Execution Context condition enables you to setup an Alarm Detection base on selected Pico Instance, except platform.
The Unreachable Execution Context condition
Item | Description |
---|---|
Event Properties | |
Pico Instance | Select a Pico instance for configure alarm, it can be Platform, EC |
Unreachable due to normal shutdown | Unchecked this checkbox to ignore the pico unreachable due to shutdown by purpose. |
Limits | Enable "During Last" checkbox to further focus on the X duration of Minutes/ Hour. |
Workflow Alarm Value
The Workflow Alarm Value condition is a customizable alarm condition. It enables you to have the Alarm Detection watch over a variable that you create and assign through the APL code. To apply the Workflow Alarm Condition use the following guidelines:
...